Annual certification and tagging
Every unit is pressure-checked, weighed, examined for physical damage and corrosion, and tagged with the date and the technician who did the work. The tag is the document the fire marshal looks for first.
NFPA 10 · TITLE 19
Annual certification, recharge, hydrostatic testing and new units sized to the hazard. Every extinguisher on your property gets inspected, tagged and recorded in one visit — and the report reaches your inbox the same day.
Every unit is pressure-checked, weighed, examined for physical damage and corrosion, and tagged with the date and the technician who did the work. The tag is the document the fire marshal looks for first.
Any unit that has been discharged — even partially, even by accident — gets recharged on the spot where we can, or swapped for a loaner while it is serviced. A discharged extinguisher on a wall is worse than no extinguisher: it reads as protected and is not.
Stored-pressure dry chemical units get opened, the agent inspected for caking, the valve and siphon tube checked, and the unit reassembled and re-pressurised. This is the interval most vendors quietly skip.
Cylinders are pressure-tested to confirm the shell is still sound. Units that fail are replaced, not patched.
We walk the space, work out the hazard class and the travel distance, and tell you what you actually need — including where it goes on the wall. Amerex, Ansul, Badger, Buckeye and compatible equipment.
A short session with your people on how to actually use one. Most staff have never pulled a pin. It takes twenty minutes and it is the difference between a small fire and a claim.
| Interval | Work performed | Standard |
|---|---|---|
| Monthly | Visual inspection — pressure, access, seal, initialed record | NFPA 10 |
| Annual | Full maintenance and a new dated certification tag | NFPA 10 · Title 19 |
| 6 years | Internal examination on stored-pressure dry chemical units | NFPA 10 |
| 12 years | Hydrostatic cylinder test | NFPA 10 |
Intervals follow NFPA 10, NFPA 17A and California Title 19. Your local authority having jurisdiction can require more frequent service — in Alameda County we confirm with the fire district before we quote.
Almost none of these are equipment failures. They are dates, positions and paperwork — which is exactly why tracking them is the service.
The single most common write-up. The equipment is fine; the date passed. We track your intervals and call you before they lapse.
An extinguisher behind a stack of boxes is a violation. So is an empty bracket where one used to hang.
If you cook with vegetable oil or animal fat, an ABC unit is not enough. Class K is required alongside the kitchen hood suppression system, and inspectors check for it specifically.
Under-pressurised or over-pressurised, both fail. A gauge in the green is the only reading that passes.
Two different things happen on two different schedules. A visual inspection is done monthly — you or your staff can do this, and it gets initialed on the tag. A full maintenance and certification has to be done annually by a licensed company, which is what NFPA 10 and California Title 19 require. On top of that, stored-pressure dry chemical units get an internal examination at six years and a hydrostatic cylinder test at twelve.
It is the dated record attached to the unit showing that a licensed technician inspected and serviced it, and when. It is the first thing a fire marshal looks at, because it is the only visible proof that the extinguisher has been maintained. No tag, or an expired tag, is treated the same as no service.
If you cook with vegetable oil or animal fat in a commercial kitchen, yes — and it is required in addition to the hood suppression system, not instead of it. Class K uses a wet chemical agent that cools burning oil and forms a crust over it. An ABC dry chemical unit sprayed into a fryer can spread the fire instead of stopping it.
You normally get a correction notice with a deadline to fix it, and a re-inspection. Depending on the jurisdiction and whether it is a repeat finding, it can carry a fee. The practical cost is usually the disruption, not the fine — and for a restaurant it can hold up other approvals.
We service Amerex, Ansul, Badger, Buckeye and compatible equipment, and carry parts and agent on the truck for the units we see most across Oakland, Hayward and the rest of the East Bay. That means most calls close on the first visit instead of waiting on a part.
It depends on the hazard class of what you store or do, the floor area, and the maximum travel distance someone should have to walk to reach one. It is not a guess — we walk the property, work it out and tell you what is required. That walk-through is free and takes under an hour on most properties.
Same-week scheduling in these cities. The rest of the Bay Area by request.
The 30-second monthly and 90-minute annual battery tests, documented. Most failed inspections here are a dead battery nobody checked — not a missing fixture.
Semi-annual service on Ansul, Pyro-Chem, and compatible industrial systems. Nozzles, fusible links, cylinder pressure — and we coordinate the hood cleaning so it happens in one window instead of three.
We walk the property, count the units and send a flat-rate quote. No commitment and no sales pressure — if your current vendor is doing fine, we will tell you that too.